Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
Add filters








Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 555-558, 2013.
Article in Chinese | WPRIM | ID: wpr-440517

ABSTRACT

Objective To compare radiation dose and image quality of prospectively ECG-triggered sequence acquisition mode and Flash(high-pitch spiral acquisition)mode in DSCT angiography of children with congenital heart disease.Methods Sixty children with clinically suspected congenital heart disease and undertook DSCT prospectively ECG-triggered scan were enrolled in the study and randomly divided into two groups.The Flash mode and prospective sequence scanning mode were applied in group A and B,respectively.The CT dose index(CTDIvol),dose length product(DLP),effective dose(E),and image quality were compared between two groups.Refered to surgery or cardiac angiography(DSA),the diagnostic coincidence rates were compared between two groups.Results The CTDIvol in group A and B was(0.32 ± 0.10)and(1.40 ± 0.43)mGy(t=13.32,P<0.05),respectively.The DLP was(6.46 ±1.92)and(17.91 ±4.80)mGy·cm(t=7.97,P<0.05).E was(0.19±0.05)and(0.45±0.12)mSv (t=16.64,P<0.05).The image quality score in group A(4.03 ± 1.15)was higher than that in group B (3.13 ± 1.38)(t=3.55,P<0.05).The total diagnostic coincidence rates were 100%(A)and 93% (B).But the deformity diagnostic coincidence rates in group A(91%)was higher than that in group B (75%)(x2=7.72,P<0.05).Conclusions In DSCT diagnosis of congenital heart disease in children,using flash scan mode can reveal more cardiac deformities than using prospective sequence scanning mode,and could reduce the radiation dose.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 95-97, 2011.
Article in Chinese | WPRIM | ID: wpr-405383

ABSTRACT

Objective To evaluate the radiation dose and image quality of MinDose techniques in dual-source CT coronary artery angiography.Methods 120 consecutive patients undergoing cardiac CT scans were randomly assigned into 2 groups: Group A1 with the tube current reduced to 20% of the normal tube current outside the pulsing window,and Group A2 with the tube current reduced to 4% of the normal tube current outside the pulsing window (MinDose).The image quality,noise,volume CT dose index (CTDIvol),and effective dose (E) of these two groups were evaluated.Results The mean score of imaging quality of Group A1 was (4.3 ± 0.3 ),not significantly different from that of Group A2 [(4.5 ±0.4),t=0.16,P>0.05].The value of CTDIvol of Group A1 was (40.2 ±9.6) mGy,significantly higher than that of Group A2 [( 36.4 ± 9.1 ) mGy,t = 3.2,P < 0.05].The E value of Group A1 was (9.1± 2.2) mSv ,significantly higher than that of A2 [( 8.1 ± 1.9) mSv,t = 2.7,P < 0.05].Conclusion Application of the MinDose technique not only reduces the radiation dose to the patient,but also meets the requirement of diagnosis.

3.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592812

ABSTRACT

Objective To evaluate the clinical application of the auto trigger technique with dual-source CT in cerebral and cervical vessel. Methods 35 patients were randomly divided into three groups, taking triggered threshold as 20HU,50HU and 70HU respectively, CT-values in segments of left middle cerebral artery, superior sagittal sinus, left common carotid artery adjacent to the fourth cervical vertebrate and internal jugular vein by injection at antecubital vein were all measured. Results The discrepancy of peak in artery among groups was not statistically different. It was statistically different in the same segments of vein. Conclusion CTA of cerebral and carotid arteries with the dual-source CT triggered technique can be clearly showed with 20HU as triggered threshold.

4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592810

ABSTRACT

Objective To introduce the techniques and clinical application of coronary arterial calcification measurements by using the multi-slice CT (MSCT). Methods The recent literature on the coronary artery calcium scoring with MSCT were reviewed. The data acquisition, image reconstruction, quantification methods in assessment of calcium and usefulness of calcium scoring in coronary artery disease were investigated. Results MSCT with nearly isotropic volumetric imaging data, subsecond rotation and retrospective electrocardiographic gating could provide better input data for quantification of coronary arterial calcium volume. Conclusion MSCT allows more precise and repeated measurement of coronary arterial calcification with low interexamination variability.

5.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592780

ABSTRACT

Objective With the increasing of the CT examination, the dose of x-ray has been brought to public attention. For the sake of making the MDCT technology better applied, available optimal technology has to be used to reduce the x-ray dose to the patients. Methods Many optimal technologies were involved in, such as ECG modulation, cardiac bowtie, 3D dose modulation, compact geometry design, electron collector and speed 4D CARE dose. Results The result of the research showed that the dose of scanning x-ray of CT could be decreased sharply by using optimal technologies. The Q2 values was the standard which could well evaluate the quality of the CT′s images and the dose of x-ray. Conclusion The quality of images and the dose of x-ray can′t be separated, which must be quoted together.

6.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592777

ABSTRACT

Objective To study how to finish radiography work satisfactorily under emergency situations. Methods Analyses and sum-up were performed from three aspects, including X -ray diagnostic vehicle, radiography and PTSD. Results The vehicle-mounted X-ray machine was kept good state during high strength utilization. 620 cases from the disaster area were examined and the diagnosing quality was better than usual. Conclusion Such aspects are very important for emergency application of vehicle-mounted X-ray machine as the daily maintenance of the machine, high technical level and proper mental intervention.

7.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592764

ABSTRACT

Objective To investigate the advantages of BLADE technique in MR T2WI/TSE abdomen scanning. Methods 36 cases, which had obvious motion defects with conventional T2WI/TSE axial abdomen scanning because of psychology or disease, performed T2WI/BLADE/TSE scan with the same regions. Then the image quality was compared, and amendment of motion defects was reviewed. The equipment was SIEMENCE 3.0T scanner and phased-array coil. Results Motion defects of all images with T2WI/BLADE/TSE were attenuated with different degree compared with T2WI/TSE. All images with T2WI/BLADE/TSE satisfied the diagnostic demand. Conclusion The BLADE technique in abdomen scanning solves the difficult problem of impossible MR scan with uneven breath and trembling patients because of psychology or disease, and obtains good diagnostic imaging.

8.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-592740

ABSTRACT

Objective To investigate the possibility to create versatile system recovery disc for PACS workstation using the software Ghost 11. Methods Firstly, PACS and Windows software was installed into a PACS workstation. Secondly, S&R&S V9.7 1112F intelligent system -packaging tool and DllCacheManager_V1.6 Dllcache backup -restore tool were used to package the system. Finally, Ghost 11 was adopted to produce mirror image of the system. Results The image could recover system easily. Conclusion The system-recovery disc created by Ghost11 can significantly minimized the workload when the PACS workstation runs into error and improves the maintenance efficiency.

9.
Journal of Practical Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-537035

ABSTRACT

Objective To study the clinical applications of SIVP detecting hepatocarcinoma in cirrhosis.Methods 40 cases of cirrhosis combined with hepatocarcinoma diagnosed by operation and pathology were collected.Control group were scaned with conventional technique,experimental group were scaned with SIVP.Results Only 5 cases catched the optimal scan timing in control group,the accuracy of diagnosis in hepatocarcinoma was 70%;All the cases found the optimal scan timing in experimental group,the detectable rate of hepatocarcinoma was 95%.Conclusion SIVP can find out the optimal timing,which greatly improved accuracy of diagnosing hepatocarcinoma in cirrhosis.

10.
Journal of Practical Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-538147

ABSTRACT

Objective To analysis the CT features in 7cases of rare adrenal interstitial tissue tumors.Methods 7 cases of rare adrenal interstitial tissue tumors were verified with operation and histology.2 cases were cyst and 2 were lipoma,neurofibroma,neurilemoma and mesenchymoma was 1 case,respctively.Results Adrenal cyst and lipoma appered the density of water and fat.neurofibroma and neuriemoma were slightly low density mass,without enhancement.There were cystic lesion in neurilemoma.Mesenchymoma had slight or moderate enhancement.Conclusion It is difficult or impossible to distinguish nuerofibroma,neurilemoma or mesenchymoma from non-function adenoma or pheochromocytoma except adrenal cyst and lipoma.

11.
Journal of Practical Radiology ; (12)1996.
Article in Chinese | WPRIM | ID: wpr-537896

ABSTRACT

Objective To analysis diagnostic CT findings of adrenocortical carcinoma.Methods To collect 13 adrenocortical carcinomas verified by operation and pathology from 1990 to 1999.Results 8 cases were functional tumor and 5 were non-function mass.The diameter of 10 cases was more than 5 centimeters.The density of carcinoma was not equality and necrosis was often be found.The edge of 6 cases were clear and 7 were not clear,3 cases had local invade and metastasis.Conclusion CT can diagnose most of functional adrenocortical carcinoma with clinic syndrome but can not differentiate non-function adrenocortical carcinoma from pheochromocytoma.

12.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-591855

ABSTRACT

The construction of 64-slice-dual-source computed tomography(DSCT) is introduced.Its imaging principle and clinical application are put forward.DSCT has special advantages in diagnosing coronary stricture.The principles of DSCT and energy subtraction imaging are expatiated in detail.DSCT has great value in clinical research and application.

13.
Journal of Practical Radiology ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-545655

ABSTRACT

Objective To investigate the methods and the value of computer virus prevention in picture archiving and communication system(PACS).Methods By establishing a safe and sound management system which employed both hardware and software preventive measures,and strengthening security awareness in personnel,virus infection in PACS was prevented.Results A marked improvement compared to previous network environment was achieved and the virus infection rate reduced by 80%,that were ensuring secure and stable operations of PACS served accurately and efficiently for hospitals and departments.Conclusion Security measures discussed above are effective in preventing computer virus in local area network systems.

14.
Journal of Practical Radiology ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-537444

ABSTRACT

Objective To analysis the CT features and differential points of adrenal myelolipoma.Methods The CT and clinical information of 9 adrenal myelolipomas were collected.Results CT diagnosed 8 cases of adrenal myelolipoma except 1 case misdiagnosing as adenoma.All mass measuring 2.8~10.5 cm in diameter with clear edge,low attenuation value of fat and irregular linear shadow of soft tissure might be seen in mass.Conclusion CT is the best examination of diagnosing,which could show the position,component of the mass and organs around it.

15.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-596961

ABSTRACT

Objective To investigate the CT findings and guidance significance of multi-slice computed tomography(MSCT) in aortic intramural hematoma(IMH).Methods The clinical data and MSCT findings of 35 cases of aortic intramural hematomas diagnosed by MSCT with continuous volume scanning were analyzed.Results The direct signs of IMH were crescent or circular thickening of aortic wall without intimal flap and true and false lumens in all 35 patients.The indirect signs were penetrating ulcer(18 cases),calcification ingression(7 cases),atherosclerosis(16 cases)and single or bilateral pleural effusion(21 cases).The complicated signs were aneurysms(5 cases) and typical type B aortic dissection(3 case).Conclusion MSCT is a fast and noninvasive examinational technique,by which the direct,indirect and complicated signs of aortic IMH can be clearly revealed.All these signs have important guidance values for clinical diagnosis and management.

16.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-596960

ABSTRACT

Objective To prospectively evaluate the effects of heart rate and heart-rate variability on dual-source computed tomographic coronary image quality in patients with high heart rates,and to determine retrospectively the accuracy of dualsource computed tomographic diagnosis of coronary artery stenosis in the same patients.Methods The image quality and diagnostic accuracy were compared between the normal group of 40 patients whose heart rates exceeded 70 beats/min and the control group of 40 patients whose heart rates were 70 beats/min or slower.Results No statistically significant differences between the groups were found in diagnostic-image quality scores of total segments or of any coronary artery,nor were any significant differences found between the groups in the accurate diagnosis of angiographically significant stenosis.Calcification was the chief factor that affected diagnostic accuracy.In high -heart -rate patients,heart -rate variability was significantly related to the diagnostic image quality of all segments(P=0.001) and of the left circumflex coronary artery(P=0.016).Heart-rate variability more than 5 beats/min most strongly contributed to an inability to evaluate segments in both groups.When heart rates rose,the optimal reconstruction window shifted from diastole to systole.Conclusion The image quality of dual -source computed tomographic coronary angiography at high heart rates enables sufficient diagnosis of stenosis,although variability of heart rates significantly deteriorates image quality.

17.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-596950

ABSTRACT

Objective To study the effect of image quality and radiation dose by using Z -axis automatic tube current modulation(ATCM),as well as the application of automatic tube current modulation technology.Methods A control group consisting of 25 patients underwent cervical MDCT with fixed-current technique(100-220mA).Of two study groups of 25 patients,one underwent cervical MDCT using z-axis ATCM with the noise index of NI10 and tube current intensity of 80-480 mA,and the other with the noise index of NI12.5 and tube current intensity of 80-369 mA.The noise and mean tube current-time products(mAs) were recorded.Two radiologists evaluated images for diagnostic acceptability.Results All CT examinations of study and control groups were diagnostically acceptable,though objective noise was different with z-axis ATCM than with fixed current.ATCM resulted in significant radiation dose reduction(NI10,94.8?17.9 mAs;NI12.5,74.8? 18.3 mAs),when compared with the fixed current(130.4?43.1 mAs).Conclusion Z-axis Automatic mA technique has no significant change in image quality when compared with the fixed mA technique,but the radiation dose is decreased by 27%(NI10) and 43%(NI12.5),for MDCT evaluation of neck.NI has to be selected on the basis of the tissue,lesion size and nature.

SELECTION OF CITATIONS
SEARCH DETAIL